Categories
Article No. 296.050.701
Technical specification
SPD type T2  
Number of poles 2  
max. discharge current (Imax) 40  
Nominal line voltage Un DC 1000  
Impulse current [Iimp]_(10/350) 5  
Nominal discharge surge current (8/20) 15  
Voltage protection level [Up] 2.6  
Operation voltage max. [Uc] ≤1200VDC  
Follow current [IF] 0  
Response time [ta] ≤25 ns  
Short circuit resistance (Icw) 1  
Fault indication mechanisch, Rot  
Temperature range -40.0 - 85.0
Total discharge current (8/20) (L N-PE) 60  
Material housing  
Signaling on the device optisch  
Signaling contact Yes  
Connection cross section solid / stranded max. 1.5  
Switching capacity signaling contact 250 V/0,5 A (AC) / - 30 V / 2 A (DC)  
Energetically coordinated protective effect to the terminal Yes  
System configuration DC Yes  
Construction size 3 TE  
Nominal discharge current [In] 15/Pol  
Integrated backup fuse No  
Nominal cross section conductor 2.5 - 25.0 mm²
Exhausting No  
Mounting method DIN rail (top hat rail) 35 mm  
Degree of protection (IP) IP20  
Casing
degree of protection IP65  
number of modules 8  
contract rail DIN-Schiene  
String / MPP 2ST - 1MPP  
inputs PG / MC4 MC 4  
outputs PG / MC4 MC 4  
Switch
Switching capacity voltage max. Uoc Max. 1000  
Switching current max. Isc. Max. 30  
Cross-sectional area 6  
Standards
Test standards Germany  
Test standards USA UL 1449 ed.3  
Test standards Europe EN 50539-11  
Test standards France UTE C61-740-51  
comment d)  
Commercial specification
Customs number 85372000  
country of origin CH  
Texte
comment d)